Frequency Inverter  PR7000 Series

Specifications and features for PR7000 series drive

Combination of 16 microprocessors, space voltage vector control and random PWM control.
Free running through Keypad Control and Analogue Control.
Multi-speed control(including multi-speed running, automatic circulating running, 8-stage speed running, compound speed control).and code timing speed control, PC or PLC speed control.Jogging speed control, external analog signal speed control, definition for definable terminals.
Stall adjustment and output with restriction on currents£»Output torque promotion, Speed-drop and Automatic slip compensation£»Current Coefficient and Output Current Compensation.
Timing Control and the Token Output.
DC braking+Optimized Energy - Consumption braking.
Controlled by keypad, 485 communication control box, PC and PLC, and 125 pieces of inverters can be operated at the same time£¬ Standard Modbus Communication.

Items

Contents

Input

Rated Voltage Range

Three-phase 380V¡À15%;
single-phase 220V¡À15%

Rated Frequency

50/60Hz

Output

Rated Voltage Range

Three-phase 0¡«380V; Three-phase 0¡«220V

Frequency Range

0.50¡«400.0Hz

V/F Control

Control Mode

Linear V/F control;
space voltage vector£«random PWM

Frequency Resolution

Max 0.01Hz, adjustment allowed

Torque Promotion

Torque Promotion curve (V/F) can be set within 1¡«16;

Stall Prevention

Current output is restricted, and threshold current
can be adjusted.

Overload Capacity

150% rated current,1minute

Operation Function

Frequency Setting

Potentiometer or external analog signal
(0¡«5V, 0¡«10V, 0¡«20mA); keypad (terminal)
¡ø£¯¨‹ keys, external control logic and PLC setting.

Start/Stop Control

Passive contact switch control or
keypad control

Frequency Change Rate

0.1¡«3000S (time required for certain frequency change)

Protection
Function

Input out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance

Display

LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter.

Environment
Conditions

Equipment Location

Free of tangy caustic gases or dust

Environment Temperature

-10¡æ¡«+50¡æ

Environment Humidity

Below 90% (no water-bead coagulation)

Vibration Strength

Below 0.5g (acceleration)

Height above sea level

1000m or below

 Applicable Motor

0.4¡«630KW