Items |
Contents |
Input |
Rated Voltage Range |
3-phase 380V¡À15%;
single-phase 220V¡À15% |
Rated Frequency |
50/60Hz |
Output |
Rated Voltage Range |
3-phase 0¡«380V;3-phase 0¡«220V |
Frequency Range |
0.00¡«650.0Hz |
Control
Mode |
Carrier Frequency |
3000~10000Hz |
Input Frequency Resolution |
Digital setting: 0.01Hz, analog setting: max frequency¡Á0.1% |
Control Mode |
SensorlessVector Control (SVC), VVVF control |
Start Torque |
0.5 Hz / 150% (SVC) |
Speed-control Scope |
1:100 (SVC) |
Steady Speed Precision |
¡À0.5%£¨SVC£© |
Torque Control Precision |
¡À0.5%£¨SVC£© |
Overload Capacity |
150% rated current, 60 seconds. |
Torque Elevating |
Auto Torque elevating, Manual Torque Promotion 0.1%~30.0% (VVVF) |
V/F Curve |
3 kinds of modes: beeline type, square type and under-defined V/F curve. |
DC Braking |
DC braking frequency: 1.0~5.0 Hz, braking time: 0.0~10.0s |
Jogging Control |
Jogging frequency range: min frequency ~ max frequency, jogging acceleration & deceleration time: 0.1~3000.0s |
Auto Circulating Running and multi-stage speed running |
Auto circulating running or terminals control can realize 16-stage speed running. |
Built-in PI adjusting |
easy to realizeConvenient form a system for process closed-loop control |
Automatic Voltage Rectification (AVR) |
Enable to keep output voltage constant automatically in the case of change of grid voltage. |
Operation Function |
Frequency Setting |
Potentiometer or external analog signal (0¡«5V, 0¡«10V, 0¡«20mA); keypad (terminal)¡ø£¯¨‹ keys, external control logic and automatic circulation setting. |
Start/Stop Control |
Passive contact switch control, keypad control or communication control. |
Running Command Channels |
Three kinds of channels from keypad panel, control terminal and series communication port. |
Frequency Source |
Frequency sources: given digit, given analog voltage, given analog current and given series communication port. |
Accessorial frequency Source |
Flexible implementation of five kinds of accessorial frequency fine adjustments and frequency compound. |
Protection Function |
Input out-phase, Output out-phase, input under-voltage, DC over-voltage, over-current, over-load, current stall, over-heat, external disturbance |
Display |
LED nixie tube showing present output frequency, present rotate-speed (rpm), present output current, present output voltage, present linear-velocity, types of faults, and parameters for the system and operation; LED indicators showing the current working status of inverter. |
Environment Conditions |
Equipment Location |
In an indoor location, Prevent exposure from direct sunlight, Free from dust, tangy caustic gases, flammable gases, steam or the salt-contented, etc. |
Environment Temperature |
-10¡æ¡«+50¡æ |
Environment Humidity |
Below 90% (no water-bead coagulation) |
Vibration Strength |
Below 0.5g (acceleration) |
Height above sea level |
1000m or below |
Applicable Motor |
0.4¡«315KW |